Meters
Read each channel’s level as RMS, peak, peak hold and Leq, set the weighting and time constant, and switch to DB Only for big numbers you can read across the room.
Levels are in dBFS: decibels below your interface’s full scale. Once a channel is calibrated, its meter also shows dB SPL.
The meter strip
Section titled “The meter strip”In the RTA, Spectrograph and RTA + Spectrograph layouts, the meter strip runs along the bottom. It starts with the signal generator, then has one meter per input channel.
Each meter shows:
- A bar with the RMS level, a peak-hold marker and a scale from −60 dBFS.
- RMS, with the time weighting in brackets, for example RMS (slow), in dBFS.
- Peak: the sample peak.
- Hold: the highest peak recently reached.
- Leq: the average level over the Leq window.
- SPL, in dB SPL, for a calibrated channel. If SPL can’t be trusted right now, the meter says SPL hidden with the reason. If the browser didn’t confirm its voice processing is off, SPL shows with caveat: unverified capture. See Getting audio in.
On each meter:
- Calibrate… opens the calibration dialog for that channel. See Calibration.
- Show big number collapses the meter to one large figure: SPL for a calibrated channel, RMS otherwise. Show full meter brings the rest back.
- Click the meter to select its channel. The selected channel has a coloured edge, draws on top of the spectrum, and is the one the spectrograph draws and Capture saves.
Metering settings
Section titled “Metering settings”The Metering section of the control rail sets how the meters measure. Hover a setting’s name for an explanation.
- Weighting: Z (flat), A or C. It applies to the meters only. The spectrum stays unweighted.
- Time weighting: Fast (125 ms) or Slow (1 s). Slow is what an SPL meter reads for a steady level.
- Leq window (s): how many seconds Leq averages over. Leq is a flat average of the power over the window, not the decay that Fast and Slow use.
- Leq in meters: tick Alongside RMS to show Leq on the DB Only tiles next to the main figure.
These settings also drive the generator meter and the level bars on transfer function cards.
DB Only
Section titled “DB Only”Set Layout to DB Only, or press M, for a tile per channel with one big figure, sized to fill the screen. Press M again to go back to RTA.
Pick the big figure with Read in the top bar:
- RMS: the RMS level, with the time weighting.
- Peak: the sample peak.
- Leq: the Leq over your window. Until the window has filled, the tile reads settling.
Each tile shows:
- The big figure, in dB SPL for a calibrated channel. For a channel that isn’t calibrated, or whose SPL can’t be trusted, it shows dBFS at the same size, with the reason next to it. A tile never shows a confident SPL number it can’t back up.
- The weighting and readout above it, for example Z / RMS / Slow.
- Peak and Hold at a fixed size, always visible. CLIP appears beside the peak when the channel reaches full scale (0 dBFS).
- Leq, when Alongside RMS is ticked and the big figure isn’t already Leq.
Click a tile to select its channel.
DB Hidden
Section titled “DB Hidden”DB Hidden removes the meter strip so the plot gets the whole height. It’s only on the Layout picker, never on a key. To pick a channel in this layout, use the Ch buttons at the top right of the plot.