Getting audio in
Choose a microphone or audio interface, allow microphone access, set the channel count, and start and end a capture. Check the capture status and what your browser can do.
Everything here sits at the left of the RTA’s top bar. On a phone, it’s in the Audio panel. See The RTA on your phone.
Allow microphone access
Section titled “Allow microphone access”Browsers hide your audio devices’ names until you let the page use the microphone. Until then the device list reads Click the mic button to grant permissions to see names, and the top bar says Click the mic button to allow microphone access.
- Click the mic button (Allow microphone access) next to the channel count.
- Allow the browser’s prompt.
The device names appear. If you blocked access earlier, the top bar says Microphone access is blocked. Allow it in the browser’s site settings. Change the setting for SoundBase in your browser’s site settings, then click the mic button again.
If a device you just plugged in doesn’t appear, click Refresh devices (the circular arrow).
Choose a device
Section titled “Choose a device”Open the device list (Choose a device…) and pick your interface or microphone.
The list also has Signal Generator: a built-in test source that needs no microphone. Its channels carry the generator’s signal, so you can try the RTA and set up the screen anywhere. See Signal generator.
When you come back to the RTA, Harmony picks the device you used last, if it’s still connected.
Channels
Section titled “Channels”Set how many input channels to capture, from 1 to 8, in the box next to the device list. Each channel gets its own meter and its own colour on the plot. The channel count is locked while a capture is running: End, change it, and Start again.
A transfer function needs at least two channels.
Output device
Section titled “Output device”For a real device, a second list picks where the signal generator plays: Default output, or one of your outputs. If you don’t choose one, Harmony uses the output on the same interface as your input when it can find it.
If the output you chose last time isn’t connected, the list shows Saved output missing and the warning Saved output not found. Using the default output.
Firefox can’t choose an output, so it shows System default output instead of a list.
Start and end a capture
Section titled “Start and end a capture”Click Start. The plot and meters come alive, and the analyzer settings in the control rail become available.
Click End to stop. The device, channel count and output can only be changed while the capture is stopped.
The capture keeps running when you switch to another Harmony tab, and the header shows Mic live until you end it. See The RTA.
If the device can’t be opened, the reason appears in red under the top bar.
Check the capture status
Section titled “Check the capture status”While a capture is running, the top bar shows the sample rate and the number of input channels the device actually delivered, for example 48000 Hz · 2 ch.
Next to that are three badges for the browser’s voice processing:
- AGC: automatic gain control rides the input level, so dB readings drift and calibration is meaningless.
- EC: echo cancellation subtracts what the browser thinks came from the speakers.
- NS: noise suppression gates steady sounds, including the noise and tones you’re trying to measure.
All three must be off for a measurement. Each badge shows the browser’s answer: green off when the browser confirmed it off, red on when it reports it on, and grey ? when it didn’t say. Hover a badge for the details.
Harmony asks the browser to turn all three off. If one is still reported on, a red banner says SPL is hidden: dBFS readings carry on, but they aren’t calibrated levels while processing is on. If the browser doesn’t report one, a yellow banner says the capture is unverified, and SPL is shown with that caveat.
Browser differences
Section titled “Browser differences”Hover the ? next to the device list for a summary. In short:
- Firefox captures more than two channels from a multichannel interface. Use it when you need channels 3 to 8. It can’t choose an output device for the generator, but it can play on any output channel.
- Chrome, Edge and other Chromium browsers capture stereo. You can ask for more channels, but you get two. They can choose an output device, with left and right output channels.
- Safari, and every browser on iPhone and iPad, captures mono or stereo only. Safari turns noise suppression off together with echo cancellation and doesn’t report it separately. It also tends to shift its input latency during a measurement, which matters for transfer functions.
SoundBase Desktop runs the RTA on the same audio engine as Chrome, so the Chromium notes apply there.