The RTA

Harmony’s real-time analyzer: bring in a microphone or audio interface, read the spectrum, meters and spectrograph, measure transfer functions, and save traces to the show.

The RTA measures sound live, in the browser, from any input your computer or phone can see:

  • Spectrum. A real-time analyzer from 1-octave to 1/48-octave resolution, with averaging and peak hold.
  • Meters. RMS, peak, peak hold and Leq per channel, in dBFS, or in dB SPL once a channel is calibrated. DB Only turns them into big, room-readable numbers.
  • Spectrograph. A scrolling waterfall of one channel’s spectrum over the last 10 seconds to 5 minutes.
  • Transfer function. Magnitude, phase, coherence and impulse response between a reference and a measurement mic, with delay finding. Needs SoundBase Pro.
  • Signal generator. Pink noise, white noise, sine and square waves, played out of your interface or used as a test source.
  • Traces. Freeze the live curve as a trace, and keep it in the show for everyone working on it.

Open the show in Harmony and click the RTA tab in the Harmony header. See Get started with Harmony.

You see the RTA tab if you have access to it. If you don’t, the tab isn’t there.

  • The top bar holds the audio device controls and Start/End, the capture status, the View, Layout and Read pickers, and the session menu (the gear).
  • The control rail, on the left, holds the analyzer settings: Display, Averaging, Peak hold and Metering, plus Transfer and Spectrograph when those are on screen. The settings are greyed out until a capture is running.
  • The plot shows the spectrum, the spectrograph, or the three transfer function panes.
  • The Traces sidebar, on the right, lists the show’s traces and has the Capture (Space) button. Drag the divider between the plot and the sidebar to resize it.
  • The meter strip, along the bottom, starts with the signal generator and then has one meter per channel. In the Transfer view it holds the transfer function cards instead.

On a screen narrower than 950 pixels the RTA switches to a compact layout with a bar of buttons along the bottom. See The RTA on your phone.

View switches between Spectrum and Transfer. Transfer needs SoundBase Pro. Without it, the option carries a Pro badge and can’t be chosen. See Transfer function.

Layout decides how the plot and the meters share the screen:

  • RTA: the spectrum plot, with the meter strip below.
  • Spectrograph: the waterfall in place of the spectrum, with the meter strip below.
  • RTA + Spectrograph: the spectrum above the waterfall, with the meter strip below.
  • DB Only: the meters fill the screen as big numbers, and the plot and the Traces sidebar hide.
  • DB Hidden: the meter strip hides, and the plot takes the whole height.

The two spectrograph layouts are for the Spectrum view only. In the Transfer view they’re greyed out, with Spectrum mode only.

Read picks which number the DB Only view makes big: RMS, Peak or Leq. See Meters.

Harmony remembers the view, layout and readout you chose. They also go into the page address, so a link to the RTA opens on the same view.

The session menu (the gear at the right of the top bar) lists them under Keyboard:

Key Does
Space Capture trace
V Restart average (in the Transfer view, restarts every transfer function’s average)
Esc Unpin cursor
M Toggle DB Only (a second press goes back to RTA)
T Toggle Transfer view

Shortcuts don’t fire while you’re typing in a field, or while a menu or dialog is open. M never chooses DB Hidden: the meters can’t vanish from a key pressed by accident.

The capture keeps running when you switch to another Harmony tab, so you can watch the stage plot while the RTA listens. While it’s running and you’re on another tab, the Harmony header shows a pulsing red Mic live button. Click it to go back to the RTA, where End stops the capture.

  • Traces are saved to the show. Everyone you’ve shared the project with sees them, and they’re there the next time you open the RTA on any device.
  • Your setup stays in this browser: the audio devices you’ve used, channel calibrations, analyzer settings, transfer function pairs, generator settings and the screen layout. Each show keeps its own. Another person, or you on another computer, starts from the defaults.

To take your setup to another computer, or to hand it to someone, export the session. See Saving and sharing sessions.

  • Getting audio in: choosing a device, microphone permission, channels, Start and End, and browser differences
  • Spectrum analyzer: resolution, averaging, peak hold, the cursor and choosing a channel
  • Traces: capturing the live curve, and showing, renaming, recolouring and deleting traces
  • Spectrograph: the waterfall, its history, colours and dB range
  • Meters: the meter strip, readouts, weighting, Leq and the DB Only view
  • Calibration: turning dBFS into dB SPL with a calibrator, a trusted meter, or a known offset
  • Signal generator: signals, level, outputs A and B, and warnings
  • Transfer function: pairs, delay finding, coherence blanking and latency correction (SoundBase Pro)
  • Saving and sharing sessions: exporting and importing .harmony files
  • The RTA on your phone: the compact layout, its bottom bar and touch controls