Skip to content

Format Wizard

Build Long Name, short label and Alias values for a whole sheet of ports from one recipe, check them against the system’s character limits, then copy them for your intercom software or write them back to the system.

The Format Wizard works on a working copy of rows. Nothing on the system changes until you click Update Stored.

  1. Select a single system or frame in the systems list.
  2. Click Toolbox in the toolbar and choose Format Wizard.

See Toolbox for who can open it.

The wizard has three parts:

  • The header bar: the Rows menu, the field you’re building, the joiner and uppercase controls, and Copy.
  • The recipe strip: the blocks that build the field.
  • The preview table: every row, with the result for the field and a character meter.

Open the Rows menu and choose where the rows come from:

  • Paste Clipboard: reads a port list or name list you’ve copied, for example from Riedel Director or a spreadsheet. Your browser may ask for permission to read the clipboard.

  • Paste Manually: opens Paste names or Director ports, a box to paste or type CSV or names into. Click Load Rows. For large lists, Paste Clipboard is quicker.

  • Add Blank Rows: set how many rows (64 by default, up to 999) and click Add Blank Rows. Type each row’s source text in the preview table.

  • Load from System: loads rows from this system’s sheets, so you can write the results back later. Choose a scope:

    • All Ports, or All Party Lines
    • By type: one port type
    • By card / UIC: one card, or one media on a card
    • By media

    Each scope shows how many rows it holds. If the system has no ports or partylines yet, the menu says Import Ports or Party Lines on this system first. See Systems.

  • Clear All Rows empties the working copy.

The field menu in the header bar picks which field the recipe builds:

System Fields
Riedel Long Name, Local 8-char, Alias
RTS Description 1, Name 4, Alias
Other systems Long Name, Local 8-char, Alias

Each field has its own recipe, so you can build all three in turn on the same rows.

The recipe strip reads <field> = followed by blocks. With no blocks, the field is copied through as it is. Click + Block to add one, then choose its type:

  • Text: fixed text, such as a show prefix.

  • # Seq: a numbered sequence. Set a Prefix (for example T2T, RTR or BOL), a Start number and the number of Digits (2 digits gives 01, 02, 03). A preview of row 1 is shown beside it.

  • From row: a column from each row, such as Long Name / Description, Port, Node-Bay, Port Type or Device. For Port and Node-Bay you can pull out part of the value:

    • From Port: Media.Port (1.34), Media only (1), Port only (34), M + media (M1) or P + port (P34).
    • From Node-Bay: Bay number (5), B + bay (B5) or Bay + number (Bay5).

    Add text before or after the extracted value with the pre and suf boxes.

  • Type-in: a value you type per row, in the Type-in column of the preview table. Press Enter to move to the next row.

Drag a block by its handle to reorder it, and click its remove button to delete it.

In the header bar:

  • joiner puts the same characters between every block: a pipe, a hyphen, spaces or anything else.
  • AA forces the whole field to uppercase.

The preview table shows the result for the field on every row, with a meter counting the characters left. The meter shows a warning colour when a value is within four characters of the limit or over a soft limit, and turns red when it’s over a hard limit.

  • To change one row’s result without changing the recipe, edit it in the table. Click ↺ (Reset to recipe) to go back to the recipe’s value.
  • Use Working Cols, Show All and Columns to choose which columns the table shows. Drag a column header to reorder it, or its edge to resize it.
System Field Limit Type
Riedel Long Name 32 Hard
Riedel Local 8-char 8 Hard
Riedel Alias 8 Hard
RTS Description 1 24 Soft
RTS Name 4 4 Soft
RTS Alias 8 Soft

A soft limit only warns. A hard limit is one Riedel Director refuses on import, so the Format Wizard won’t copy or write back a field while any row is over it. The header bar shows how many rows are over limit.

Clear-Com systems have no limits set yet, so no meters are shown. Hardwire and custom systems use the Riedel limits.

When Copy or Update Stored is refused, a list of the rows over the limit opens above the preview table: <count> <field> values are over the limit. Fix them there and click Apply to these rows.

For a single value, the cell’s Over limit: fix tools menu offers:

  • Edit: type a new value.
  • Cut to <n> Chars: keep the start and cut off the end at the limit.
  • Strip Spaces: remove every space from the value.
  • Copy <field> in the header bar copies the field for every row as one column. Paste it into the matching column of your intercom configuration software, such as Riedel Director. Your browser may ask for permission to write to the clipboard.
  • Update Stored <field>, above the preview table, writes the field back onto the system. It’s available only for rows you loaded with Load from System. Nexus asks Update stored labels? and confirms how many rows it will write. Only that field changes: Other columns are left alone.
  • Clipboard blocked: your browser refused clipboard access. Allow it for SoundBase, or use Paste Manually.
  • Clipboard empty: copy a port list or name list first.
  • Could not parse paste: the pasted text wasn’t a list Nexus could read. Check it, or paste it into Paste Manually to edit it.
  • Update Stored is greyed out: load the rows with Load from System first.