Riedel
Plan a Riedel Artist or Bolero system in Nexus: import ports and conferences from Director, work across linked frames, and copy finished labels back to Director.
Subsystems
Section titled “Subsystems”Set the system’s Subsystem on the Summary tab:
- Standalone Bolero
- Integrated / Artist, then the frame: G-2 Frame or 1024 Frame
Each Artist frame is its own system. Two or more Artist frames on one show are linked: the Systems rail groups them under Riedel, and requesters see one combined pick list. Select the group heading for the combined All frames view, which lists every frame’s rows together. A Standalone Bolero stays separate. See Linked frames.
To plan a frame’s cards and ports before you have a Director file, use the Frame Planner.
Sheets
Section titled “Sheets”A Riedel system has Ports, PLs / Groups, IFBs and ISOs tabs, alongside Summary, Equipment, Crew and any custom tabs.
Shown by default: Pick list, Long Name, Short label (Director: Local 8-char Label), Alias, Subtitle and Type (Director: Port Type).
You can also show Location (Node-Bay), Port # (Port), Device, Room (Room Code), Status, IP in 1 and IP out 1 (the input and output media 1 IP addresses), Trunk addr (Trunking object address), Full Name, Position and Tags.
Type on an imported port is locked to what Director exported. On a port you add by hand, Type suggests Director’s own port types as you type, and also takes your own text (No match. Press Enter to add a custom type). If what you type looks like another brand’s equipment, Nexus asks: “[text]” looks like [brand] [model]. Are you sure you’re in the correct system?
PLs / Groups
Section titled “PLs / Groups”Long Name, Short label, Alias, Kind and Notes, plus Members, GPIO out and Trunk addr you can switch on. Kind is Conference or Group.
Director’s dynamic conferences (DYNACONF) show as Dynaconference. They stay visible but are read-only, can’t be selected and can’t go on the pick list.
IFBs and ISOs
Section titled “IFBs and ISOs”- IFBs: Name, Input, Mix minus, Output, IFB group and Notes.
- ISOs: Long Name, Short label, Alias and Notes.
To see Director’s names on every header, open a tab’s Tab settings menu and choose Match device (Riedel) labels.
Label rules
Section titled “Label rules”Nexus checks Riedel values against Director’s limits as you type:
- Long Name: 32 characters
- Local 8-char Label and Alias: 8 characters
- Subtitle: 16 characters
- Room Code: Room A to Room Z, then Room 1 to Room 228
- IP Address (Input Media 1) and IP Address (Output Media 1): a valid IPv4 address
See Fix values that break the label rules.
Import from Director
Section titled “Import from Director”Nexus reads Director’s list exports directly. In Director, copy the port list or the conference and group list (Director’s copy tree contents), then paste it into the Nexus import wizard.
- Open the Riedel system’s Ports or PLs / Groups tab and click Import.
- Paste into Or paste here, or drop a saved export.
- Nexus reports Riedel ports or Riedel conferences & groups and how many rows it found. Check the Add to pick list options (Panels, Bolero / wireless, or Conferences & groups, plus Skip rows with no name).
- Click Import.
Nexus reads each port’s equipment from Director’s Port Type, not from its name, so a port you’ve renamed is still classified correctly. Panels and beltpacks go on the Equipment tab automatically.
If the paste covers several frames, the wizard asks how each frame lands. See Review frames. The toast after a ports import lists the ports, panels and wireless packs found and how many went on the pick list.
Supported Director versions
Section titled “Supported Director versions”Nexus imports port and conference exports from every Director version from 6.8 to 8.9:
- 6.8 and 6.9
- 7.1, 7.2, 7.3 and 7.4
- 8.0, 8.1, 8.2, 8.3, 8.4, 8.5, 8.6, 8.7, 8.8 and 8.9
You don’t need to say which version you’re on. Nexus recognises it from the export’s headers.
Older versions export less than current ones:
- Columns added in later Director versions come in blank.
- Director 8.6 and later export each port’s Node-Bay, which places ports on their frame and bay. Earlier versions don’t, so check the frame layout after importing a multi-frame list.
Importing again
Section titled “Importing again”Re-importing into a sheet that already has rows offers Update matching ports, which keeps your aliases, tags and pick list. Nexus withholds it, and offers Replace all rows or Add as new rows instead, when it can’t match ports safely:
- The saved rows and the new paste identify ports differently, for example when the sheet was first imported from Director 8.5 or earlier and the new paste is from 8.6 or later.
- The export has ports that share an address. Nexus imports them separately, but Director can reorder them after a rename.
A damaged paste
Section titled “A damaged paste”Nexus checks the row count Director writes at the top of every export. If rows are missing, it stops: Director says this list has [n] rows, but [m] were pasted. Part of the list is missing. Copy it from Director again.
Copy ports back to Director
Section titled “Copy ports back to Director”Once your labels are finished, copy them back into Director one column at a time.
Frame order and Source order
Section titled “Frame order and Source order”The Ports tab’s toolbar has two orders:
- Frame order (the default): bay, then port, the way the frames are laid out. Easiest to work in.
- Source order: the order Director lists the ports in. Use this for the first paste into a fresh Director build, where ports still show their factory names.
Copy a column
Section titled “Copy a column”- Click Copy for Director.
- Choose a column: Long Name, Local 8-char Label, Alias, Subtitle, the four IP Address columns, Input Gain, Output Gain, Room Code, Trunking object address, Keypad Shortcut or Active Source Channel.
- In Director, select the same column and paste.
The first time you copy from a system, Nexus explains Source order (Looks like your first time…). Tick I understand, then choose Use Source order & copy or Keep current order & copy.
If any value in the column is over Director’s limit, a popover lists them ([n] [field] over limit). Edit them there or click Cut all to limit, then Apply & copy. The fixes are saved before the copy. The toolbar also shows [n] over limit while any Long Name, Local 8-char Label or Alias is too long.
When Copy for Director is unavailable
Section titled “When Copy for Director is unavailable”Nexus can only rebuild Director’s order for ports that came from one Director paste:
- Nothing to export. Import a Director port list first.
- Rows added by hand or mapped from a spreadsheet have no position in Director’s list.
- A table that mixes several imports: export one paste at a time, or replace the table.
- A paste that covered several frames: copy from the All frames view, because Director lists the frames together. On a single frame, Source order shows Only this frame’s rows… with a View All frames button.
Room codes
Section titled “Room codes”Riedel systems can plan Director room codes for crew who carry more than one device. See Room codes.